The store will not work correctly in the case when cookies are disabled.
Programmable Industrial 4-port USB Switch for USB-C
₹90,300.00
(B2B customers can get this product at ₹ 76525 by availing GST input credit)
In stock
SKU
Industrial-USB-C-4-Port-Switch
-
Delivery is estimated within 25 days of order confirmation.
-
Price is inclusive of GST and Import duty charges
-
Buy on EMI starting at 1824/month
-
The product is eligible for Free Shipping
Programmable Industrial 4-port USB Switch for USB-C
- Enable/Disable any port
- Automate type-C hot-plug / unplug actions
- Automate type-C connector flip actions (using Acroname UOC cable)
- Customize USB signal equalization settings (Redriver option only)
- Monitor voltage on all ports
- Monitor current on the common port
- Monitor voltage and current on CC and VCONN
- Individually enable/disable SuperSpeed and HiSpeed data, CC, SBU and power connections for any port
- Maintain software control through a dedicated control port
- Separate or combine USB lines between Mux Channels using advanced SPLIT mode
- MacOSX 10.8+, Linux, ARM6, ARM7, and Windows 7, 8 and 10 (32bit and 64bit) platform support
- Python, C, C++, .NET and LabVIEW APIs
- Selectively connect one USB Type-C?? (USB-C) connection to any one of 4 channels
- Bidirectional 1:4 or 4:1 configurations
- All ports support USB 3.2 (Gen 2x2, 20Gbps)
- All ports support USB PD profiles up to 100W (20V, 5A)2 Æ’?? Execute USB-C cable flip via software
control3
- Supports pass through of USB Alt-Modes
- Available in Passive or Redriver versions
- DIN rail mountable using C31-DINM-1
- Certified to withstand ?ñ15kV ESD strikes
More Information
specification |
Typical Performance Characteristics
Parameter |
Conditions/Notes |
Min |
Typ |
Max |
Units |
VBUS common to mux port ON |
|
200 |
250 |
350 |
mΩ |
VBUS current measurement resolution |
|
- |
1.95 |
- |
mA |
VBUS current measurement accuracy |
|
- |
±0.5 |
- |
%FS |
VBUS voltage measurement resolution |
|
- |
8 |
- |
mV |
VBUS voltage measurement accuracy |
|
- |
±0.2 |
- |
%FS |
CCx current measurement resolution |
|
- |
976 |
- |
µA |
CCx current measurement accuracy |
|
- |
±0.5 |
- |
%FS |
CCx voltage measurement resolution |
|
- |
4 |
- |
mV |
CCx voltage measurement accuracy |
|
- |
±0.5 |
- |
%FS |
Keep-alive charge (KAC) voltage |
Sourced from control port VBUS |
4.5 |
5.0 |
5.5 |
V |
Keep-alive charge (KAC) current limit |
Constant current mode short circuit to ground |
600 |
800 |
1000 |
mA |
A5 common to A5 mux DCR |
|
1.0 |
- |
1.1 |
Ω |
B5 common to B5 mux DCR |
|
1.0 |
- |
1.1 |
Ω |
A5 common to B5 mux DCR |
Software flip condition |
1.0 |
- |
1.1 |
Ω |
B5 common to A5 mux DCR |
Software flip condition |
1.0 |
- |
1.1 |
Ω |
|